Description
SUN-5K-P1
Deye Hybrid Inverter, 1 phase, 2 MPPT, 48V, 5kW
Datasheet:
SUN-5K-P1
- Colourful touch LCD
- IP65 protection degree
- 6 time periods for battery charging/discharging
- Max. charging/discharging current of 190A
- AC couple to retrofit existing solar system
- Support storing energy from diesel generator
- Max.16 pcs parallel for on-grid and off-grid operation
- Support multiple batteries parallel
Model | SUN-5K-P1 |
---|---|
Battery Input Data | |
Battery Type | Lead-acid or Lithium-ion |
Battery Voltage Range (V) | 40-60 |
Max. Charging Current (A) | 120 |
Max. Discharging Current (A) | 120 |
Charging Curve | 3 Stages / Equalisation |
External Temperature Sensor | Yes |
Charging Strategy for Li-Ion Battery | Self-adaption to BMS |
PV String Input Data | |
Max. DC Input Power (W) | 6500 |
Rated PV Input Voltage (V) | 370(125~500) |
Start-up Voltage (V) | 125 |
MPPT Voltage Range (V) | 150-425 |
Full Load DC Voltage Range (V) | 300-425 |
PV Input Current (A) | 13+13 |
Max. PV ISC (A) | 22+22 |
Number of MPPT Trackers | 2 |
Number of Strings per MPPT Tracker | 1+1 |
AC Output Data | |
Rated AC Output Active Power (W) | 5000 |
Max. AC Output Power (W) | 5500 |
AC Output Rated Current (A) | 20.8/24 |
Max AC Output Current (A) | 22.9/26.4 |
Max. Continuous AC Passthrough (A) | 50 |
Peak Power (off grid) | 2 time of rated power, 10 S |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
Power Factor | 1 |
Output Frequency and Voltage | 50 / 60Hz; L1/L2/N(PE) 120/240Vac (split phase), 208Vac (2/3 phase), L/N/PE 220/230Vac (single phase) |
Grid Type | Split phase; 2/3 phase; Single Phase |
Total Harmonics Current Distortion (THDi) | <3% (of nominal power) |
DC Current Injection | <0.5% In |
Efficiency | |
Max. Efficiency | 97.60% |
Euro Efficiency | 97.00% |
MPPT Efficiency | 99.90% |
Protection | Integrated “Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection” |
Over Voltage Category | DC Type II / AC Type â…¢ |
Certifications and Standards | |
Grid Regulation | EN 50549, UNE 217002, NRS 097, IEEE 1547.1, SRD V2.0 |
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2, UL 1741 |
General Data | |
Operating Temperature Range (℃) | -40~60℃, >45℃ Derating |
Cooling | Smart Cooling |
Noise (dB) | ≤30 dB |
Communication with BMS | RS485; CAN |
Weight (kg) | 32 |
Cabinet Size (WxHxD mm) | 420×670×233 (Excluding Connectors and Brackets) |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
Warranty | 5 Years (10 Years Optional) |