SUN-50K-3P
Deye Hybrid inverter, 3- phase, 50Kw, 160-800V, 4 MPPT, 50000W
Datasheet:
SUN-50K-3P
- 127V/220V, 133V/230V and 50/60Hz, Three phase system
- 4 MPP tracker, Max. efficiency up to 98.7%
- Zero export application, VSG application
- String intelligent monitoring (optional)
- Wide output voltage range
- Anti-PID function (Optional)
Parameter | SUN-50K-G-LV |
---|---|
PV String Input Data | |
Max. PV Input Power (kW) | 65 |
Max. PV Input Voltage (V) | 800 |
Start-up Voltage (V) | 250 |
MPPT Voltage Range (V) | 200-700 |
Rated PV Input Voltage (V) | 400 |
Max. Operating PV Input Current (A) | 40+40+40+40 |
Max. Input Short Circuit Current (A) | 60+60+60+60 |
No. of MPP Trackers/No. of Strings per MPP Tracker | 4/4+4+4+4 |
AC Input/Output Side | |
Rated AC Output Active Power (kW) | 50 |
Max. AC Output Apparent Power (kVA) | 50 |
Rated AC Output Current (A) | 131.3/125.4 |
Max. AC Output Current (A) | 131.3/125.4 |
Rated Output Voltage/Range (V) | 127V/220V, 133V/230V 0.85UN-1.1UN |
Grid Connection Form | 3L/N/PE |
Rated Output Grid Frequency/Range (Hz) | 50/45-55, 60/55-65 |
Power Factor Adjustment Range | 0.8 leading-0.8lagging |
Total Current Harmonic Distortion THDi | <3% |
DC Injection Current | <0.5%ln |
Efficiency | |
Max. Efficiency | 98.7% |
MPPT Efficiency | >99% |
Equipment Protection | |
DC Polarity Reverse Connection Protection | yes |
AC Output Overcurrent Protection | yes |
AC Output Overvoltage Protection | yes |
AC Output Short Circuit Protection | yes |
Thermal Protection | yes |
DC Terminal Insulation Impedance Monitoring | yes |
DC Component Monitoring | yes |
Ground Fault Current Monitoring | yes |
Power Network Monitoring | yes |
Island Protection Monitoring | yes |
Earth Fault Detection | yes |
DC Input Switch | yes |
Overvoltage Load Drop Protection | yes |
Residual Current (RCD) Detection | yes |
Surge Protection Level | TYPE II(DC),TYPE II(AC) |
Interface | |
Communication Interface | RS485/RS232 /WiFi/LAN |
General Data | |
Operating Temperature Range (°C) | -25 to +60℃, >45℃ Derating |
Permissible Ambient Humidity | 0~100% |
Permissible Altitude (m) | 2000m |
Noise (dB) | ≤55 dB(A) |
Ingress Protection (IP) Rating | IP 65 |
Inverter Topology | Non-Isolated |
Over Voltage Category | OVC II(DC),OVC III(AC) |
Cabinet Size (WxHxD mm) | 700×575×297 (Excluding Connectors and Brackets) |
Weight (kg) | 60 |
Warranty (year) | 5 years |
Type Of Cooling | Intelligent Air Cooling |
Grid Regulation | NBR 16149, NBR 16150, EN 50549, RD 140 |
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |