Description
SUN-16K-P3
Deye Hybrid inverter, 3- phase, 16K, 230/400VAC, 16000W
- Colourful touch LCD
- IP65 protection degree
- 6 time periods for battery charging/discharging
- Max. charging/discharging current of 290A
- Support storing energy from diesel generator
- AC couple to retrofit existing solar system
- Max. 16 pcs parallel for on-grid and off-grid operation
- Support multiple batteries parallel
Specifications:
Category | Specification |
---|---|
Model | SUN-16K-P1 |
Battery Input Data | |
Battery Type | Lead-acid or Lithium-ion |
Battery Voltage Range (V) | 40~60 |
Max. Charging Current (A) | 290 |
Max. Discharging Current (A) | 290 |
Charging Curve | 3 Stages / Equalisation |
External Temperature Sensor | Yes |
Charging Strategy for Li-Ion Battery | Self-adaption to BMS |
PV String Input Data | |
Max. DC Input Power (W) | 20800 |
Max. DC Input Voltage (V) | 500 |
Start-up Voltage (V) | 125 |
MPPT Range (V) | 150~425 |
Rated DC Input Voltage (V) | 370 |
PV Input Current (A) | 26+26+26 |
Max. PV ISC (A) | 44+44+44 |
No.of MPPT Trackers | 3 |
No.of Strings Per MPPT Tracker | 2+2+2 |
AC Output Data | |
Rated AC Output Active Power (W) | 16000 |
Max AC Output Active Power (W) | 17600 |
Rated AC Output Current (A) | 72.7/69.6 |
Max AC Output Current (A) | 80/76.5 |
Max. Continuous AC Passthrough (A) | 100 |
Peak Power (off grid) | 2 times of rated power, 10S |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
Rated Input/Output Voltage/Range(V) | 220/230 0.85Un-1.1Un |
Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz |
Grid Connection Form | L+N+PE |
Total Harmonics Current Distortion (THDi) | <3% (of nominal power) |
DC Current Injection | <0.5% 1n |
Backup Data | |
Backup Power (W) | 14000 |
Backup Rated Current (A) | 63.6/60.9 |
Backup UPS | 4ms Automatic switchover time |
Efficiency | |
Max. Efficiency | 97.60% |
Euro Efficiency | 96.50% |
MPPT Efficiency | 99.90% |
Integrated | Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection |
Over Voltage Category | DC Type II/AC Type III |
Certifications and Standards | |
Grid Regulation | IEC 61727, IEC 62116, AS 4777.2, NRS 097 |
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
General Data | |
Operating Temperature Range (℃) | -45~60℃, >45℃ Derating |
Cooling | Smart Cooling |
Noise (dB) | ≤30 dB |
Communication with BMS | RS485; CAN |
Weight (kg) | 48.5 |
Cabinet Size (WxHxD mm) | 464×763×282 (Excluding Connectors and Brackets) |
Protection Degree | IP65 |
Installation Style | Wall-mounted |
Warranty | 5 Years/10 Years (the Warranty Period Depends on the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy) |